Robust, Dependable UV Solution
Our smallest wastewater system in terms of flow-handling, the TrojanUV3000™PTP (Packaged Treatment Plant), is ideally suited to treat flows up to 2.8 MGD (442 m3/hr).
The TrojanUV3000PTP can be equipped with pre-fabricated stainless steel channels and transition boxes for in-line integration with existing flanged piping – thus minimizing engineering and installation costs.
Easily Retrofitted
It can be easily retrofitted into existing chlorine contact tanks and effluent channels, and comes pre-tested, pre-assembled and pre-wired to minimize installation costs.Proven, Chemical-Free Disinfection from the Industry Leader
Using Trojan’s most proven, modular design and robust components, including low-pressure lamps, these systems are straightforward to operate and require minimal operator involvement. This flexible system has demonstrated effective and reliable performance around the world.
Common replacement parts for the TrojanUV3000PTP:
- # 302417, # 302418
- # 302108, # 302208
- # 302403
- # 321159
Typical Applications
Lamp Type
- Up to 3 MGD (473 m3/hr)
Ballast Type
- Low-pressure
Input Power Per Lamp
- Electronic; non-variable
Lamp Configuration
- 45 or 87.5 Watts
Module Configuration
- Horizontal, parallel to flow
Bank Configuration
- 2 or 4 lamps per module
- Up to 10 modules per bank
Lamp Banks in Series
Channel Options
- Up to 2
Level Control Device Options
- Stainless Steel (Trojan option)
- Concrete (by others)
- Fixed weir
System Monitor/Control Center
Ballast Enclosure
- 304 stainless steel
Ballast Cooling Method
- TYPE 6P (IP67)
Installation Location
- Convection; no air conditioning or forced air required
- Indoor or outdoor
Controller
UV Intensity Monitoring
- Optional; Monitoring only
Local Status Indication
- Optional
Remote Alarms
- Lamp Age (hours)
- UV Intensity (mW/cm2)
- Bank Status (on/off)
- Low Intensity Alarm
- Lamp Failure Alarm
- UV Intensity (4-20 mA)
- Common Alarm (discrete)
Power Distribution
Quantity Required
- Individual GFI Receptacles
Power Input
- 1 receptacle per 2 modules
- 120V, single phase
Secondary & Tertiary Effluent UV Disinfection
The vast majority of wastewater treatment plants around the world provide secondary treatment through conventional activated sludge processes. Some plants have tertiary treatment processes that use an additional filtration process to further improve water quality. The resulting effluent typically requires a disinfection step before discharge back to the environment.Chlorine Conversion to UV Disinfection
Chlorine gas has traditionally been used for wastewater disinfection for many years. Sodium hypochlorite (liquid bleach) is an alternative to chlorine gas; however, it is more costly and has the same environmental concerns. UV disinfection can easily be retrofitted into an existing chlorine contact tank and has significant benefits compared to chlorine disinfection.
Request a Quote
Gallery
Modular Design (Phot... In this 0.13 MGD (20.5 m3 hr) installation, the modular design of the...
Multiple Configurati... The UV system can be configured to have more than one UV bank - thereby...
Plug and Play (Photo... The UV modules plug into a GFI receptacle, as seen in this 1.0 MGD (158...
Flexible Installatio... The modules can be installed in a concrete channel or in a pre-fabricated...
Contact Us
3020 Gore Road, London, Ontario Canada, N5V 4T7- Office:
- +1 (519) 457-3400
- Office:
- +1 (888) 220-6118
- Fax:
- +1 (519) 457-3030